• Users Online:97
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 


 
 Table of Contents  
REVIEW ARTICLE
Year : 2015  |  Volume : 2  |  Issue : 3  |  Page : 225-231

Jugular venous oximetry


Department of Anaesthesia and Intensive Care, PGIMER, Chandigarh, India

Date of Web Publication10-Sep-2015

Correspondence Address:
Dr. Hemant Bhagat
Department of Anaesthesia and Intensive Care, PGIMER, Chandigarh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2348-0548.165046

Rights and Permissions
  Abstract 

The measurement of saturation of venous blood as it drains out of brain by sampling it from the jugular bulb provides us with an estimate of cerebral oxygenation, cerebral blood flow and cerebral metabolic requirement. Arterio-jugular venous difference of the oxygen content (AVDO 2 ) and jugular venous oxygen saturation (SjVO 2 ) values per se helps clinicians in identifying the impairment of cerebral oxygenation due to various factors thereby prompting implementation of corrective measures and the prevention of secondary injury to the brain due to ischaemia. SjVO 2 values are also used for prognostication of patients after traumatic brain injury and in other clinical situations. Sampling and measuring SjVO 2 intermittently or continuously using fibreoptic oximetry requires the tip of the catheter to be placed in the jugular bulb, which is a relatively simple bedside procedure. In the review below we have discussed the relevant anatomy, physiology, techniques, clinical applications and pitfalls of performing jugular venous oximetry as a tool for measurement of cerebral oxygenation.

Keywords: Cerebral oxygenation, jugular bulb, jugular venous oximetry


How to cite this article:
Bhardwaj A, Bhagat H, Grover VK. Jugular venous oximetry. J Neuroanaesthesiol Crit Care 2015;2:225-31

How to cite this URL:
Bhardwaj A, Bhagat H, Grover VK. Jugular venous oximetry. J Neuroanaesthesiol Crit Care [serial online] 2015 [cited 2019 Jan 16];2:225-31. Available from: http://www.jnaccjournal.org/text.asp?2015/2/3/225/165046


  Introduction Top


Minimising secondary injury to the brain after a primary insult forms the backbone of intervention in neuroanaesthesia and neurointensive care. However, in order to achieve this it is of absolute importance to identify the insult as promptly as possible so that appropriate intervention can be instituted. The salvageable portion of the brain, that is, the penumbra requires a constant supply of oxygen so that it does not undergo irreversible brain damage. Jugular bulb oximetry is one such monitor, which provides information about the status of cerebral oxygenation and helps in guiding the therapy to prevent secondary injury due to various factors.

Percutaneous sampling and analysis of human cerebral venous blood from the jugular bulb was first described by Myerson et al. in 1927. [1] Subsequently Gibbs et al. in 1942 studied the arteriovenous difference between oxygen, glucose and lactate content and proposed them as measures of the balance between oxygen supply and demand. [2] It is more than six decades now that the measurement of oxygenation of the jugular venous blood is being used to monitor the cerebral physiology. [3] As of now, jugular venous oxygen saturation (SjVO 2 ) provides us information about the balance between cerebral oxygen supply and demand, and is used to guide physiologically based management of various clinical situations including traumatic brain injury, during neurosurgery and cardiopulmonary bypass. [4],[5],[6] Oxygen that is not utilised by the brain is carried into the systemic circulation via internal jugular veins (IJVs), and hence, the measurement of SjVO 2 helps to determine the balance between cerebral blood flow (CBF) and cerebral metabolic requirement of oxygen (CMRO 2 ).


  Clinical Anatomy Top


Blood from the brain drains mainly through the venous sinuses. Almost whole of the blood comes into the right and left sigmoid sinus, which continue downwards as respective IJVs after passing through the jugular foramen. The jugular bulb is the dilatation of the jugular vein as it exits from the base of the skull. The tip of the catheter is placed in the jugular bulb for withdrawal of a sample or continuous monitoring of SjVO 2 [Figure 1]. The jugular bulb contains the blood, which is being drained out from both sides of the brain, out of which around 70% is from the same hemisphere and 30% is from the opposite hemisphere. [7],[8] Most of the patients will have a dominant side of the venous drainage and in the majority of them it will usually be right. [9],[10] The side with major venous drainage, as seen on the cerebral angiogram, gives an idea about the side of dominance.
Figure 1: Jugular bulb anatomy

Click here to view


The comparison of jugular foramen size using computed tomography scan can also be used to predict the side of the predominant drainage, with the larger size of foramen corresponding to the side of the major drainage. [11] Ultrasonography can also be used to compare the size of the veins with the vein having larger diameter being the one with dominant drainage. The patients in whom the intracranial pressure (ICP) is being monitored, the dominant vein can be determined by the one with a higher rise in ICP following manual compression of each side. It is assumed that compressing the side with more drainage will cause a greater increase in ICP as a larger portion of cerebral outflow will be occluded. [12]


  Monitoring Site Top


Patients sustaining an injury to both the hemispheres of the brain should have a catheter placed in the jugular bulb on the side of major drainage, which in most of the cases is generally right. [10] However, if the patient has a focal injury, then there are no clear cut guidelines regarding the side on which the catheter should be placed. As more than two-third of the blood from the brain is drained through the ipsilateral IJV, it may be reasonable to cannulate the IJV on the side of the lesion, even if it is not the side with dominant drainage. [5]


  Techniques of Measurement Top


A catheter that is used to monitor the SjVO 2 is almost same as the one, which is used to monitor the central venous pressure. The catheter is inserted in the IJV in a retrograde direction and the tip is advanced up to the jugular bulb. Intermittent samples may be drawn and SjVO 2 measured. [13] It is important to note that the rate of aspiration of blood for measurement should be <2 ml/min to avoid contamination from extracranial vessels. Fibre optic technology has allowed the development of in vivo catheters wherein reflectance oximetry using such catheters allows continuous SjVO 2 monitoring, thus obviating the need for repeated sampling and measurement. [14],[15]

Oxyhaemoglobin has a unique light absorption spectrum and this forms the basis of fibreoptic oximetry. Catheters that are used to measure SjVO 2 contains two optical fibres, one of which is used to direct the light into the blood and the other one is used to transmit the reflected light to a sensor. The sensor measures the absorped light which is reflected at different wavelengths. The SjVO 2 values are therefore a percentage of oxygenated haemoglobin to the total haemoglobin. These catheters using a dual wavelength of light (Edslab, Baxter-Edwards system) require that the haemoglobin concentration of the patient to be manually entered. The SjVO 2 values are thus dependent on the values entered. Alternatively, the catheters which use three wavelengths (Opticath Oximetrix, Abbott Critical Care System) calculate the haemoglobin concentration from the absorption spectrum itself and hence can be used for a real time, continuous monitoring of SjVO 2 .


  Catheter Insertion Top


Puncture site for insertion is similar to that used for IJV cannulation. However, the needle followed by guidewire and subsequently the catheter are all advanced in a direction towards the skull [Figure 1]. To prevent injury, it is important that the tip of the guidewire is J-shaped and is advanced only 3-4 cm beyond the site of needle insertion. The catheter is advanced over the guide wire in a cephalad direction till there is a feeling of resistance at the jugular bulb. The catheter is subsequently withdrawn for about 0.5-1 cm so that that the tip does not lodge against the roof of the jugular bulb. This also reduces the risk of injury to the bulb and prevents occlusion of the catheter tip. Markings on the guidewire may also be used to help us in determining the distance to which the catheter should be inserted [Figure 2]. It should be 1 cm lesser than the length as measured from the point at which the catheter enters the neck up to the mastoid process. Skull and neck radiography can be used to confirm the correct placement of the catheter. [16] On a lateral radiograph of the neck the tip of the catheter should be at the level of mastoid process and just medial to it and also above the lower border of C1 vertebrae, as the aspiration of blood from this position will reduce the chance of contamination from extracranial vessels [Figure 3]. Alternatively fluoroscopy can also be used intraoperatively for quick confirmation of the position of the catheter tip.
Figure 2: Estimation of insertion length using a guidewire

Click here to view
Figure 3: Correct positioning of catheter tip seen on X-ray of neck and skull (lateral view)

Click here to view



  Principle of Jugular Venous Oximetry Top


Jugular venous saturation indirectly gives us an idea of the use of oxygen by the brain. To put it in simpler terms when the demand for oxygen is more, the brain extracts a greater amount of oxygen, resulting in decreased jugular bulb oxygen saturation. When cerebral oxygen supply exceeds demand, the extraction is less and saturation of oxygen in the venous blood increases. If the CBF reduces too much, then a point is reached when the neurons of the brain cannot tolerate the reduction of blood flow. After this stage is reached, the consumption of oxygen reduces leading to anaerobic metabolism and production of lactate. The oxygen saturation in jugular bulb is related to the CMRO 2 and CBF as represented by the Ficks equation:

CMRO 2 = CBF × (CaO 2 − CjO 2 )

CaO 2 (Arterial oxygen content) = SaO 2 × 1.34 × Hb + 0.0031 × PaO 2

CjO 2 (Jugular venous oxygen content) = SjO 2 × 1.34 × Hb + 0.0031 × PjO 2

The contribution from dissolved oxygen, as we know, is very small and can safely be neglected. The difference between arterial oxygen content and oxygen content of venous blood is represented as (CaO 2 − CjO 2 ) or AVDO 2 (arterio-venous oxygen difference). If the above equation is rearranged then:

AVDO 2 = CMRO 2 /CBF

Normal AVDO 2 values are between 4 ml/dl and 8 ml/dl. [17],[18] Presuming that if CMRO 2 does not change then any change in AVDO 2 should be because of the change in CBF. If AVDO 2 is <4 ml/dl of blood, it is probably because the oxygen supply is in excess of the demand (i.e. luxury perfusion or infarction). An AVDO 2 value more than 8 ml/dl of blood points towards the demand being more than the supply (i.e., ischaemia). If CMRO 2 increases but the CBF does not increase concomitantly, then there will be enhanced extraction of oxygen from the blood. There is a proportional decrease in oxygen content, as well as oxygen saturation, of the venous blood coming out of the brain with eventual widening of AVDO 2 . In a healthy brain flow-metabolism coupling is preserved and SjVO 2 ranges between 55% and 75%. [2] However in pathological conditions, the coupling between CMRO 2 and CBF is lost and in circumstances where hypoperfusion is not accompanied by proportional reduction in CMRO 2 , the brain will extract a greater proportion of arterial oxygen and SjVO 2 will be observed to fall. Values below 54% imply that oxygen supply may be critically low for the metabolic demand and the brain is at risk for ischaemic injury. [19] Value more than 75% is representative of cerebral hyperaemia or decreased oxygen extraction as in cerebral infarction.


  Determinants of Jugular Venous Oxygen Saturation Top


A reduction in SjVO 2 may be due to fall in supply of oxygen or an increase in usage of oxygen by the brain whereas an increase in SjVO 2 values may be seen due to increase in oxygen delivery or a reduction in oxygen consumption:

Decreased jugular venous oxygen saturation (<50%)

  • Due to reduced supply of oxygen: Cerebral vasoconstriction, hypocapnia, vasospasm, hypotension, anaemia and sepsis
  • Due to increased oxygen requirement: Increased cerebral metabolism, which include causes such as fever, agitation, inadequate sedation, pain and seizures.


Increased jugular venous oxygen saturation (>75%)

  • Increased supply of oxygen: Cerebral vasodilation, hypercapnia, hypertension
  • Reduced oxygen requirement: Deep sedation, coma, hypothermia, cerebral infarction, brain death.



  Clinical Applications Top


Traumatic brain injury

In patients who have sustained a traumatic brain injury, SjVO 2 monitoring provides a means to identify ischaemia, which may be due to either systemic or intracranial causes. [20],[21] The goal is to maintain a SjVO 2 value above 50% as we know that the values lesser than this suggest a relative failure of oxygen supply compared with demand and episodes of such desaturation have demonstrated to predict poor outcome after head injury. [10] Whenever hyperventilation is to be instituted, SjVO 2 monitoring is a valuable aid in guiding its optimal usage without causing cerebral hypoperfusion. [22],[23],[24],[25] As per the brain trauma foundation guidelines for the management of traumatic brain injury, prophylactic hyperventilation (<25 mm Hg PaCO 2 ) is not recommended, more so in the first 24 h after injury. If other measures to reduce ICP have failed, then hyperventilation is to be used only as a temporary measure. It is vital to monitor SjVO 2 or brain tissue oxygen tension (PBrO 2 ) while hyperventilating this group of patients. [26] SjVO 2 monitoring can also be used to guide administration of fluids and level of oxygenation [22],[25] and optimise the cerebral perfusion pressure. [21],[27],[28] A scheme for management of low SjVO 2 (<50%) in neurosurgical patients is outlined in [Figure 4]. Though low SjVO 2 predicts poor outcome but it is also important to emphasize that even SjVO 2 values >85% may be associated with a poor outcome as high values suggest a state of hyperaemia or failing oxygen utilisation either due to a state of cellular dysfunction and death or due to shunting of arterial blood. [29] The current clinical use of jugular venous oximetry in patients with traumatic brain injury is limited to prognosticate the outcome. There is no evidence to suggest that clinical management based on jugular venous oximetry values have influenced the outcome of the patient.
Figure 4: Schematic diagram of strategies to correct low jugular venous oxygen saturation

Click here to view


Lactate oxygen index (LOI) can also be used to predict outcome in traumatic brain injury patients. [10] Its normal values are <0.03 and values >0.08 are seen in patients with failing oxygen extraction, leading to failure of aerobic metabolism and increased production of lactic acid in the brain especially in the first 24 h after head injury. [30] It is calculated by the formula mentioned below:

LOI = −AVDL (mmol/lt) ×2.24/AVDO 2 (ml/dl)

AVDL = Arterial to jugular difference for lactate

AVDO 2 = Arterial to jugular difference in oxygen content.

Neurosurgery

SjVO 2 monitoring has been extensively used by Matta et al., in neurosurgical patients. [5] They demonstrated that the SjVO 2 catheter could be placed quickly and can detect frequent critical episodes of SjVO 2 desaturation that would otherwise have been undetected and untreated. During intracranial aneurysm surgery, SjVO 2 monitoring has been used to determine the minimal blood pressure that should be maintained to avoid hypoperfusion and also to measure LOI. Intraoperative LOI >0.08 during surgery for aneurysm clipping has been associated with a poor outcome. [31] SjVO 2 monitoring can also be used in any neurosurgical procedure to help in deciding the appropriate mean arterial pressure and PaCO 2 values to ensure adequate cerebral oxygenation. Our own experience suggests that measurement of SjVO 2 in patients undergoing clipping of ruptured cerebral aneurysm is feasible and can help in guiding the perioperative anaesthetic management. [32]

Cardiac surgery

Neurologic dysfunction is seen quiet commonly after cardiac surgery especially in those patients who undergo cardiopulmonary bypass. [33] Most of the episodes of SjVO 2 desaturation are seen during the period of rewarming after hypothermic cardiopulmonary bypass. SjVO 2 desaturation can result in increased incidence of post-operative cognitive dysfunction. [34],[35],[36] It would be prudent to monitor SjVO 2 during cardiac surgery to prevent these episodes of desaturation and improve the cognitive outcome. [37]

Cardiac arrest

SjVO 2 values are higher in the non-survivors than the survivors of cardiac arrest (values of 80% vs. 67%) probably due to the inability of dead neurons to utilise the supplied oxygen. [38] Moreover, SjVO 2 values more than the mixed venous oxygen saturation are also associated with poor outcome. [39] However, these findings are still controversial and have been countered by studies, which did not find any difference in the SjVO 2 values in between survivors and non-survivors of cardiac arrest. [40]

Research applications

Jugular venous oximetry can be used to guide research to evaluate the effect of various anaesthetic agents on CBF. In a recently concluded study comparing propofol and desflurane in patients undergoing clipping of aneurysmal neck after subarachnoid haemorrhage, it was observed that use of desflurane was associated with increase in SjVO 2 values indicating hyperaemia whereas SjVO 2 values were maintained within physiological range with the use of propofol indicating better flow-metabolism coupling. [32]


  Drawbacks and Limitations Top


  • It is an invasive procedure requiring the insertion of the catheter retrograde into the jugular vein. Cannulating the vein may fail at times due to anatomical variations and abnormalities. Carotid puncture and subsequent haematoma formation can also occur
  • Malpositioning of the catheter tip can occur which may give erroneous readings if the position of the tip is not confirmed prior to the measurement of SjVO 2 values
  • Mechanical complications of injury to the vessel wall or jugular bulb may occur. Infectious complications have also been reported though the incidence of such complications is very less [41]
  • Subclinical jugular vein thrombosis may occur if catheter is kept in situ for more than 6 days but the presence of such catheters has not shown to increase the ICP any further [42]
  • No consensus exists as to which side jugular bulb should be cannulated. As 70% of the cerebral venous blood drains via the ipsilateral jugular veins, some clinicians advocate cannulating the side of injury. However, in the case of diffuse cerebral injury, most clinicians would monitor the right side, as it is commonly dominant, whereas some clinicians would advocate monitoring the side of dominant flow in all situations
  • The catheter may impinge against the wall of the jugular bulb and may give false low readings in case of a continuous monitoring catheter or make aspiration of blood difficult for measurement of SjVO 2 values for intermittent monitoring
  • The catheter may also get kinked or there may be deposition of fibrin at the tip which may affect the quality of the signal. However, the current generation of catheters are stiff and less prone to kinking. They may also have an antithrombotic coating to prevent fibrin deposition. However, continuous monitoring catheters should be frequently calibrated against a co-oximeter control before instituting any therapy based on SjVO 2 values
  • If the rate of aspiration is >2 ml/min, then considerable contamination can be there from the extracranial vessels. Hence, it is important that for the catheters used for intermittent sampling the rate of aspiration to withdraw the sample should be <2 ml/min [43]
  • SjVO 2 gives an idea of global or at best hemispheric oxygenation and may have poor sensitivity for focal ischaemia, which may not be reliably detected. As a matter of fact, regions of infarcted tissue which do not utilise any oxygen due to failure of cellular metabolism and function like physiological shunts may mask the effect of surrounding ischaemic areas leading to falsely reassuring values of SjVO 2
  • It is of limited value in monitoring patients with infratentorial injuries or lesions as the brain stem and cerebellum contributes very little to the venous outflow from the brain
  • Insertion of the catheter may be difficult in patients with associated cervical spine injuries, trauma to the neck, presence of a tracheostomy tube and is contraindicated in patients with coagulopathy.



  Conclusions Top


Jugular venous oximetry is the oldest technology for the measurement of cerebral oxygenation and hence becomes a natural benchmark against which newer modalities of monitoring are evaluated. Despite its limitations, it is a relatively low-cost monitor and the fact that it can be inserted at the bedside to assess the adequacy of cerebral oxygenation makes it quite attractive. Its role becomes even more important when hyperventilation or blood pressure directed management has to be instituted for patients with traumatic brain injury and other intracranial pathologies. As a part of multimodality monitoring which includes ICP monitoring, monitoring of CBF by transcranial Doppler and assessing the adequacy of cerebral oxygen delivery at the target area by brain tissue oxygen measurement (PBrO 2 ) and cerebral microdialysis catheters, SjVO 2 monitor functions as a tool for global cerebral oxygenation and helps to guide various goal-directed therapies in the management of patients with various intracranial pathologies. It subserves as an important tool for research related to various interventions, which can influence CBF and cerebral oxygenation. Hence in the absence of other viable alternatives to measure the adequacy of cerebral oxygenation, Jugular venous oximetry will continue to thrive as a useful monitoring modality for this purpose.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
  References Top

1.
Myerson A, Halloran RD, Hirsch HL. Techniques for obtaining blood from the internal jugular vein and internal carotid artery. Arch Neurol Psychiatry 1927;17:807-8.  Back to cited text no. 1
    
2.
Gibbs EL, Lennox WG, Nims LF, Gibbs FA. Arterial and cerebral venous blood: Arterial-venous differences in man. J Biol Chem 1942;144:325-32.  Back to cited text no. 2
    
3.
Ferris E, Engel G, Stevens C, Logan M. The validity of internal jugular venous blood in studies of cerebral metabolism and blood flow in man. Am J Physiol 1946;147:517-21.  Back to cited text no. 3
    
4.
Sheinberg M, Kanter MJ, Robertson CS, Contant CF, Narayan RK, Grossman RG. Continuous monitoring of jugular venous oxygen saturation in head-injured patients. J Neurosurg 1992;76:212-7.  Back to cited text no. 4
    
5.
Matta BF, Lam AM, Mayberg TS, Shapira Y, Winn HR. A critique of the intraoperative use of jugular venous bulb catheters during neurosurgical procedures. Anesth Analg 1994;79:745-50.  Back to cited text no. 5
    
6.
Nakajima T, Kuro M, Hayashi Y, Kitaguchi K, Uchida O, Takaki O. Clinical evaluation of cerebral oxygen balance during cardiopulmonary bypass: On-line continuous monitoring of jugular venous oxyhemoglobin saturation. Anesth Analg 1992;74:630-5.  Back to cited text no. 6
    
7.
Shenkin HA, Harmel MH, Kety SS. Dynamic anatomy of the cerebral circulation. Arch Neurol Psychiatry 1948;60:240-52.  Back to cited text no. 7
    
8.
Lassen NA. Cerebral blood flow and oxygen consumption in man. Physiol Rev 1959;39:183-238.  Back to cited text no. 8
    
9.
Beards SC, Yule S, Kassner A, Jackson A. Anatomical variation of cerebral venous drainage: The theoretical effect on jugular bulb blood samples. Anaesthesia 1998;53:627-33.  Back to cited text no. 9
    
10.
Robertson CS, Narayan RK, Gokaslan ZL, Pahwa R, Grossman RG, Caram P Jr, et al. Cerebral arteriovenous oxygen difference as an estimate of cerebral blood flow in comatose patients. J Neurosurg 1989;70:222-30.  Back to cited text no. 10
    
11.
Stocchetti N, Paparella A, Bridelli F, Bacchi M, Piazza P, Zuccoli P. Cerebral venous oxygen saturation studied with bilateral samples in the internal jugular veins. Neurosurgery 1994;34:38-43.  Back to cited text no. 11
    
12.
Dearden NM. Jugular bulb venous oxygen saturation in the management of severe head injury. Curr Opin Anaesthesiol 1991;4:279-86.  Back to cited text no. 12
    
13.
Cruz J. Continuous versus serial global cerebral hemometabolic monitoring: Applications in acute brain trauma. Acta Neurochir Suppl (Wien) 1988;42:35-9.  Back to cited text no. 13
    
14.
Howard L, Gopinath SP, Uzura M, Valadka A, Robertson CS. Evaluation of a new fiberoptic catheter for monitoring jugular venous oxygen saturation. Neurosurgery 1999;44:1280-5.  Back to cited text no. 14
    
15.
Andrews PJ, Dearden NM, Miller JD. Jugular bulb cannulation: Description of a cannulation technique and validation of a new continuous monitor. Br J Anaesth 1991;67:553-8.  Back to cited text no. 15
    
16.
Bankier AA, Fleischmann D, Windisch A, Germann P, Petritschek W, Wiesmayr MN, et al. Position of jugular oxygen saturation catheter in patients with head trauma: Assessment by use of plain films. AJR Am J Roentgenol 1995;164:437-41.  Back to cited text no. 16
    
17.
Souter M, Andrews P. A review of jugular venous oximetry. Intensive Care World 1996;13:32-8.  Back to cited text no. 17
    
18.
Ritter AM, Robertson CS. Cerebral metabolism. Neurosurg Clin N Am 1994;5:633-45.  Back to cited text no. 18
    
19.
Dearden NM. SjVO 2 and critical perfusion pressure after severe brain injury. Br J Intensive Care 1992;1:7-11.  Back to cited text no. 19
    
20.
Fortune JB, Feustel PJ, Weigle CG, Popp AJ. Continuous measurement of jugular venous oxygen saturation in response to transient elevations of blood pressure in head-injured patients. J Neurosurg 1994;80:461-8.  Back to cited text no. 20
    
21.
Chan KH, Dearden NM, Miller JD, Andrews PJ, Midgley S. Multimodality monitoring as a guide to treatment of intracranial hypertension after severe brain injury. Neurosurgery 1993;32:547-52.  Back to cited text no. 21
    
22.
Thiagarajan A, Goverdhan PD, Chari P, Somasunderam K. The effect of hyperventilation and hyperoxia on cerebral venous oxygen saturation in patients with traumatic brain injury. Anesth Analg 1998;87:850-3.  Back to cited text no. 22
    
23.
Fortune JB, Feustel PJ, Graca L, Hasselbarth J, Kuehler DH, David H. Effect of hyperventilation, mannitol, and ventriculostomy drainage on cerebral blood flow after head injury. J Trauma 1995;39:1091-9.  Back to cited text no. 23
    
24.
Skippen P, Seear M, Poskitt K, Kestle J, Cochrane D, Annich G, et al. Effect of hyperventilation on regional cerebral blood flow in head-injured children. Crit Care Med 1997;25:1402-9.  Back to cited text no. 24
    
25.
Matta BF, Lam AM, Mayberg TS. The influence of arterial oxygenation on cerebral venous oxygen saturation during hyperventilation. Can J Anaesth 1994;41:1041-6.  Back to cited text no. 25
    
26.
Bratton S, Bullock MR, Carney N, Chesnut RM, Coplin W, Ghajar J, et al. Guidelines for management of severe traumatic brain injury. J Neurotrauma 2007;24:S87.  Back to cited text no. 26
    
27.
Chan KH, Miller JD, Dearden NM, Andrews PJ, Midgley S. The effect of changes in cerebral perfusion pressure upon middle cerebral artery blood flow velocity and jugular bulb venous oxygen saturation after severe brain injury. J Neurosurg 1992;77:55-61.  Back to cited text no. 27
    
28.
Cruz J. Combined continuous monitoring of systemic and cerebral oxygenation in acute brain injury: Preliminary observations. Crit Care Med 1993;21:1225-32.  Back to cited text no. 28
    
29.
Macmillan CS, Andrews PJ, Easton VJ. Increased jugular bulb saturation is associated with poor outcome in traumatic brain injury. J Neurol Neurosurg Psychiatry 2001;70:101-4.  Back to cited text no. 29
    
30.
Gupta AK, Zygun DA, Johnston AJ, Steiner LA, Al-Rawi PG, Chatfield D, et al. Extracellular Brain pH and Outcome following Severe Traumatic Brain Injury. J Neurotrauma 2004;21:678-84.  Back to cited text no. 30
    
31.
Moss E, Dearden NM, Berridge JC. Effects of changes in mean arterial pressure on SjO2 during cerebral aneurysm surgery. Br J Anaesth 1995;75:527-30.  Back to cited text no. 31
    
32.
Bhardwaj A, Bhagat H, Grover VK, Nidhi BP, Kiran J, Seelora S, et al. Comparison of outcome using propofol or desflurane for aneurysm neck clipping surgery following sub arachnoid haemorrhage. J Neuroanaesth Crit Care 2015;2:155.  Back to cited text no. 32
    
33.
Schell RM, Kern FH, Greeley WJ, Schulman SR, Frasco PE, Croughwell ND, et al. Cerebral blood flow and metabolism during cardiopulmonary bypass. Anesth Analg 1993;76:849-65.  Back to cited text no. 33
    
34.
Croughwell ND, Frasco P, Blumenthal JA, Leone BJ, White WD, Reves JG. Warming during cardiopulmonary bypass is associated with jugular bulb desaturation. Ann Thorac Surg 1992;53:827-32.  Back to cited text no. 34
    
35.
Souter MJ, Andrews PJ, Alston RP. Jugular venous desaturation following cardiac surgery. Br J Anaesth 1998;81:239-41.  Back to cited text no. 35
    
36.
Croughwell ND, Newman MF, Blumenthal JA, White WD, Lewis JB, Frasco PE, et al. Jugular bulb saturation and cognitive dysfunction after cardiopulmonary bypass. Ann Thorac Surg 1994;58:1702-8.  Back to cited text no. 36
    
37.
Schell RM, Kern FH, Reves JG. The role of continuous jugular venous saturation monitoring during cardiac surgery with cardiopulmonary bypass. Anesth Analg 1992;74:627-9.  Back to cited text no. 37
    
38.
Takasu A, Yagi K, Ishihara S, Okada Y. Combined continuous monitoring of systemic and cerebral oxygen metabolism after cardiac arrest. Resuscitation 1995;29:189-94.  Back to cited text no. 38
    
39.
Zarzuelo R, Castañeda J. Differences in oxygen content between mixed venous blood and cerebral venous blood for outcome prediction after cardiac arrest. Intensive Care Med 1995;21:71-5.  Back to cited text no. 39
    
40.
Van der Hoeven JG, de Koning J, Compier EA, Meinders AE. Early jugular bulb oxygenation monitoring in comatose patients after an out-of-hospital cardiac arrest. Intensive Care Med 1995;21:567-72.  Back to cited text no. 40
    
41.
Coplin WM, O′Keefe GE, Grady MS, Grant GA, March KS, Winn HR, et al. Thrombotic, infectious, and procedural complications of the jugular bulb catheter in the intensive care unit. Neurosurgery 1997;41:101-7.  Back to cited text no. 41
    
42.
Goetting MG, Preston G. Jugular bulb catheterization does not increase intracranial pressure. Intensive Care Med 1991;17:195-8.  Back to cited text no. 42
    
43.
Matta BF, Lam AM. The rate of blood withdrawal affects the accuracy of jugular venous bulb. Oxygen saturation measurements. Anesthesiology 1997;86:806-8.  Back to cited text no. 43
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
Abstract
Introduction
Clinical Anatomy
Monitoring Site
Techniques of Me...
Catheter Insertion
Principle of Jug...
Determinants of ...
Clinical Applica...
Drawbacks and Li...
Conclusions
References
Article Figures

 Article Access Statistics
    Viewed5347    
    Printed57    
    Emailed0    
    PDF Downloaded1297    
    Comments [Add]    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]